As a professional UV light meter manufacturer, we have developed several UV radiometers for a variety of applicable industries during the last 12 years since the foundation of Linshang. Boasting a leading research and development team and a mature, stable quality management system, Linshang has the confidence that every UV light meter can meet the user's needs.

  

According to the ultraviolet wavelength (UV-A, UV-B, UV-C, UV-V) and the type of UV lamp (high pressure mercury lamp, LED light source, etc. ), our UV light meters can be divided into a variety of models. For more questions about the UV meter selection, please read "UV Light Meter Selection and FAQ"or browse the FAQ at the bottom of this page.

LS125 Light Meter+BL-X0 Probe

1.Suitable for blue light energy and power detection

2.Spectral response range: 410nm-490nm

3.Power measuring range: 0 - 2000mW/cm²

4.Advanced digital probe technology, it has high precision and good anti - jamming ability


Browse:84

LS129 Ultraviolet Digital Probe

1.Communication protocol: MODBUS;Communication interface: RS485
2.Spectral response: 320nm-400nm;λp =365nm
3.It is convenient to communicate with PLC, human-computer interface, computer and other equipment and collect and monitor real-time data.

Browse:3283

LS331 Flaw Detection Light Meter

Specialized for non-destructive testing (NDT)

1,000,000 Lx visible light, 200,000 μW/cm² UV ultra-large range design

Adopt spectral sensor for high accuracy

Browse:239
prev 12 Next 2 pages 18 items

How to choose a suitable UV light meter?

Different wavelength ultraviolet light sources have different functions. For example, UVC wavelength ultraviolet light is generally used in the sterilization industry and UVA wavelength ultraviolet light is used in the curing industry. When choosing an UV light meter, please firstly confirm the ultraviolet light source you need to measure -type or band. This information can be obtained from the specifications of the light source being tested, or you can directly query the UV light source manufacturer.

I. Choose UV meter according to the type of UV light source

UV Light Source Suggested UV Meter

253.7nm UVC germicidal lamp 

LS126C UV light meter 
(UV meter APP+PC software)

LS125 host+UVC-X0 probe
LS125 host+UVCWP-X0 (waterproof)
LS129-UVC (online UV light monitor)

UVC LED (260nm, 275nm, etc.)

LS125 host+UVCLED-X0 probe
UV plant growth light or reptile lamp LS125 host+UVB-X0 probe

365nm high pressure mercury lamp

LS125 host+UVA-X0 probe
LS129-UVA (online UV light monitor)

UV LED 

(365nm, 385nm, 395nm, 405nm, etc.)

LS125 host+UVALED-X0 probe
(area light source)

LS129-UVALED (online UV light monitor)
LS126A UV light meter (ultra-small probe)

LS125 host+UVALED-X1 probe
point light source)

UV Halogen, gallium, iron, xenon lamps, etc. LS125 host+UVA-X0 / UVA-X1 probe
UV light source in aging box LS125 host+UVA-X1 / UVB-X0 probe
UV light from the sun LS125 host+UVA-X1/ UVB-X0 probe
Welding arc LS125 host+UVA-X1/ UVB-X0 / UVC-X0 probe
Non-destructive inspection UV lamp LS125 host+UVA-X0 probe
UV LED Nail Lamp LS125 host+UVALED-X3 probe

II. Choose UV light meter according to the UV wavelength

Suggested UV Meter UV Spectral Response UV Meter Application
LS126C UVC light meter 230-280nm

Medical 254nm UVC germicidal

low-pressure mercury lamp

LS125 host+UVC-X0 probe 230-280nm High-power 254nm germicidal mercury lamp
LS125 host+UVCWP-X1 probe 230-280nm

High-power 254nm UVC germicidal

mercury lamp, 1 meter waterproof

LS125 host+UVCLED-X0 probe 240-320nm

260-285nm LED sterilization lamp

LS125 host+UVB-X0 probe 280-315nm

297nm, 308nm, 313nm UVB light source

LS125 host+UVA-X0 315-400nm High pressure mercury lamps
LS125 host+UVA-X1  260-400nm UVA light source
LS125 host+UVALED-X0 340-420nm UV LED area light source
LS125 host+UVALED-X1 340-420nm UV LED point light source
LS125 host+UVALED-X3 probe 340-420nm

Low-power UVA LED light sources

LS126A UVA light meter 340-420nm

UV LED area light source; 

small probe or narrow space

LS129-UVA online light meter 315-400nm

High pressure mercury lamps, online

LS129-UVALED online light
meter

340-420nm

UV LED area light source,
online

LS129-UVC online light meter 230-280nm 254nm UVC germicidal mercury lamp, online


III. Choose UV intensity meter according to the measurement range and test hole diameter

Suggested

UV meter

Power Measuring
 Range

Energy/Dosage 
 Measuring Range

Measuring  Aperture

LS126C UVC light meter

0-20000 μW/cm²
0-9999999μJ/cm²
10mm

LS125 host+UVC-X0 probe

0-200000 μW/cm²
LS125 host+UVCWP-X1 probe
LS125+UVCLED-X0 probe

LS125 host+UVB-X0 probe

LS125 host+UVALED-X3 probe

LS125 host+UVA-X1 probe

LS125 host+UVA-X0 probe

0-2000 mW/cm² 0-9999999mJ/ cm²
LS125 host+UVALED-X0 probe 0-20000 mW/cm²
LS125 host+UVALED-X1 probe 1mm

LS126A UVA light meter

0-9999999mJ/cm² 3mm

LS129-UVA online
 light meter

0-2000 mW/cm² 0-4×10⁹mJ/ cm² 10mm

LS129-UVALED online
light meter

0-20000 mW/cm²

LS129-UVC online
light meter

0-200000 μW/cm² 0-4×10⁹μJ/ cm²

IV. FAQ for UV light meters

1. Why there is no traceable calibration certificate for UV LED light meters?

There are no testing standards for LED light source,  so we can't provide any traceable reports for the probes or UV intensity meters special for LED light souce (UVCLED-X0 probe, UVALED-X0 probe, UVALED-X1 probe, UVALED-X3 probe, LS126A, LS129-UVA). The data of these probes or UV meters are calibrated based on the manufacturer's standards of Linshang. 

We provide factory calibration report for all the UV light intensity meters.

2. Is there a traceable calibration certificate included?

The calibration certificate is not a standard configuration. You need to pay additional calibration costs and wait patiently for the inspection duration of the device.

All the UV light meters, except the probes or UV meters special for LED light source, conform the relevant regulations and standards in China. The UV light intensity meter can pass the inspection of authoritative measurement agency (which has been approved by CNAS and ilac-MRA) and obtain a calibration certificate.  

3. What's the value of UV germicidal lamp used in hospitals to be qualified?

The "Chinese Technical Disinfection Technical Specifications" stipulates that the UV light meter is to be placed at a distance of 1 m vertically under a 253.7 nm germicidal lamp. 

The UV light intensity of the new ordinary 30W straight tube must be no less than 100 μW/ cm²

The UV light intensity of the 30W straight tube in use must be no less than 70 μW/ cm²

The UV germicidal lamps with different wattages have various standards, while 30W straight tube is the most commonly used.

The UV light intensity of the germicidal lamp is also related to the ballast. If the ballast of poor quality is used, the qualified UV-C lamp may also be be judged as failing, we recommend that users choose ballasts with good quality, such as Philips.

4. Can these UV meters measure UV wavelength?

Sorry, Linshang UV meters can just measure UV light intensity or UV dose (also UV dosage or energy). Only spectrometers can measure the UV wavelength.

5. Two ways to figure out whether it is a 253.7nm germicidal lamp (low-pressure mercury lamp)

Option 1:The spectral response range of LS126C or other UV-C probes is 230-280nm, the measured peak wavelength is 253.7nm, while the UV light meters' response at other wavelengths is very weak. The low-pressure mercury lamp currently known only has a peak wavelength at 253.7nm. Therefore, if the test data is very low, then the germicidal lamp peak wavelength may not be 253.7nm or it's unqualified.

Option 2: A spectrometer is needed to measure the spectrum or wavelength of the germicidal lamp.(Unfortuantely this equipment is not provided by Linshang.)

6. UV light meter calibration period and cost

UV meters are generally recommended to be calibrated once a year, however, if they are not used frequently and the UV meters are kept in a dry and clean environment, you can also choose to send them back to the factory for calibration every two years or longer.

The first calibration is free, but the freight cost and VAT/taxes by customs is borne by the client. The cost of subsequent calibration for UV light meter is US$32.