The LS125 UV light meter is a host that supports 12 different probes, main function is data display. The BL-X0 probe specifically responds to wavelengths from 410nm to 490nm, dedicated to measuring the intensity and energy of 450nm blue light, such as detecting the medical phototherapy devices, LED blue therapy light, plant growth lights and so on.

LS125-Light-Meter-BL-X0-Probe
LS125-Light-Meter-BL-X0-Probe

If you want to know about other types of probes supported by the LS125 UV light meter host, please click "LS125 Multi-Probe UV light meter Host" for details.

Parameters

Parameters BL-X0   Probe
Spectral response 410nm-490nm,λp = 450nm
Power measuring range 0 - 2000mW/cm²
Resolution 0.1mW/cm²
Energy measuring range 0 - 9999999mJ/cm²
Record time 0 - 99999S
Measuring   accuracy H<5mW/cm²:±0.5mW/cm²,
H>=5mW/cm²:±10%H,(H is the standard value)
Sampling speed 2048times/second
Optional unit mW/cm² (default),W/m²
Test Hole Diameter Φ10mm
Probe size 39mm × 32mm × 15mm (L*W*H)

Features

Specialized for Blue LED Curing Lamps

BL-X0 probe suitable for testing the intensity and energy of 450nm blue light LED sources, certified by authoritative metrology institutes.

Medical phototherapy devices
LED blue therapy light
Plant growth lights

Spectral Response for Blue Light

BL-X0 probe has a spectral response range of 410nm-490nm, with a peak wavelength calibrated at 450nm and specialises in the measurement of blue light intensity and energy.

High-Speed Sampling, Accurate Data

BL-X0 probe samples at a rate of 2048 times per second, providing high-speed sampling for greater measurement accuracy.

High-Speed Sampling

Digital Probe Technology

Advanced digital probe technology, all data collection and processing is done inside the probe. It ensures excellent measurement accuracy through digital signal transmission with stronger anti-interference.

Statistical Functions

Statistical functions display real-time value, maximum value, minimum value and average value of the power simultaneously, reducing the time cost of manual recording and calculation.

Statistical Functions

Two Units Switching

Freely switch between mW/cm² and W/m² units. Data conversion between different units requires no manual calculation.

Qualifications and Standards

Qualifications and Standards

FFH1503-2015 C. M. for Irradiance Meter

Certificates for LS125 UV radiometer host +BL-X0 probe
Certificates for LS125 UV radiometer host +BL-X0 probe