LS160A Transmission Meter

Special for window tint and window film (<0.8mm)

Small size and easy to carry out
IR Rejection rate, UV Rejection rate and Visible Light Transmittance can be evaluated

Request A Quote Buy Now

LS160A solar film transmission meter is a specialized instrument for measuring the light transmission properties of various types of solar film, construction film, insulation film, insulation coating,etc. It can measure three parameters including visible light transmittance, ultraviolet-rejection rate and infrared rejection rate. The window film transmission meter has small size and it is eay to carry out.

LS160A Transmission Meter Features and Operation

Parameter

Parameter LS160A Transmission Meter
Dimension 93mm *52mm *25m (L*W*H)
Weight 70g (exclude batteries)
Maximum sample thickness <0.8mm
Resolution 0.1%
Accuracy ±2%(Colorless and transparent material)
Visible light Peak wavelength 530nm
UV Peak wavelength 365nm
IR Peak wavelength 1400nm
Display 128*128 Dot matrix LCD
Battery 4*AAA alkaline battery

Feature

Small and Delicate

LS160A is easy to carry out, and users don't need wory about the problems that due to the weight or size of the meter, which is very convenient

Operate easily and display instantly

Turn on the meter and put the material into the slot. Without no more other operation, The light transmittance, UV rejection rate and IR rejection rate can be displayed immediately on the screen, simple and fast

Real-time dynamic calibration function

The window film transmission meter has real-time dynamic calibration function. It will self-calibrate if there is no materials for testing which is to ensure the accurate test data

Lock data function

Press HOLD button can lock data on the screen even the material are taken away which is appriporate for reading

LS160A transmission meter testing state
LS160A transmission meter data locking state

Low power consumption
Save energy

Powered by 4 AAA alkaline dry batteries, ultra-low power consumption and easy replacement. The meter will automatic shutdown after 3 minutes if there is no any operation making it more power-saving and energy-saving

Qualifications and Standards

solar film tester patent certificate
solar film tester patent certificate

Packing

No. Description Quantity Unit
1 LS160A Transmission Meter   1 pcs
2 AAA battery  4 pcs
3 User Manual  1 pcs
4 Certificate / warranty card  1 pcs
5 Cloth packing bag   1 pcs
6 Screwdriver 1 pcs
7 Spare screw 1 pcs
8 Packing box dimension 15*8*5 cm(L*W*H) 1 pcs

FAQ

  1. 1.The difference between LS160 (940nm) and LS160A (1400nm) window film transmission meters

    The main difference between LS160 and LS160A is that the peak wavelength of the built-in infrared light source is different, LS160: 940nm, LS160A: 1400nm, these two wavelengths are more representative, most of the absorption film has a better rejection effect on 940nm infrared. The metallic film (insulation by reflecting heat) has a better rejection effect on 1400nm infrared. Please choose the appropriate model according to your own film category.

  2. 2. The difference between LS160A and LS162A window film transmission meters

    The appearance and size is different and the measurement parameters are basically the same; the test notch of LS160A is 0.8mm, which is only suitable for testing materials with a thickness of less than 0.8mm;

    The test notch of LS162A is 8mm, which can test films and stick-film glass. It can also directly measure automobile side windshield.

Video

Transmission Meter measured V-KOOL solar film

Transmission Meter measured 3M solar film

Transmission Meter measured Llumar solar film

Transmission Meter Selection

More about Linshang Transmission Meter price, product model selection, parameter comparison and question

More details